Terminal Block, 24V - 0V (24V Supply) - Bosch Rexroth IndraDrive HMV Project Planning Manual

Supply units and power sections
Table of Contents

Advertisement

280/369
Bosch Rexroth AG | Electric Drives
Functions and Electrical Connection Points
Properties
8.17

Terminal Block, 24V - 0V (24V Supply)

Function, Pin Assignment
View
Screw connection
M6 thread at device (terminal block)
tightening torque
power consumption
voltage load capacity
polarity reversal protection
current carrying capacity "looping through" from 24V to 24V, 0V to 0V
(contact bars in scope of supply of accessory HAS01)
with contact bars -072-
and Controls
Data
number of poles
type
design
connection cable solid wire
connection cable stranded wire
Fig.8-54:
Properties
Connection of external 24V supply:
24V supply of HMS, HMD, HCS power sections (not at HCS02)
for the power section of the drive controller
for brake control via X6
for the control section of the drive controller with the optional modules,
except for such optional modules (e.g. safety technology S1) which require
their own power supply
24V supply of HMV supply units
for the integrated electronics
for the 24V interface of the mains connection for ON/OFF control
Identifica‐
tion
+24V
0V
Unit
Nm
W
V
A
Fig.8-55:
Function, pin assignment, properties
Rexroth IndraDrive | Project Planning Manual
Unit
Min.
mm
0,5
2
0,5
mm
2
AWG
20
Function
power supply
connection to neighboring devices with contact bars from the
HAS01.1 accessory
reference potential for power supply
connection to neighboring devices with contact bars from the
HAS01.1 accessory
Min.
5,5
see P
(see index entry with reference to the corresponding
N3
page)
see U
(see index entry with reference to the corresponding
N3
page)
within the allowed voltage range by internal protective diode
220
Typ.
Max.
4
spring terminal
pins at device
1,5
1,5
16
Max.
6,5