10.1.2

Diagnostic Messages Displayed at IndraDrive M Supply Units

HMV - Diagnostic Messages for Operating States and During the Initialization Phase

press "^" key
press "Enter" key
press "Enter" key
with "v" or "^" key select the desired language
Fig.10-9:
Setting the language
For detailed descriptions of the diagnostic messages mentioned in
this chapter, see Troubleshooting Guide of the firmware documen‐
tation.
Display
VM P0
VM P1
VM P2
VM P3
VM Bb
VM bb
VM Lb
VM I Lb
VM Lb
VM charg
VM lb
Electric Drives
| Bosch Rexroth AG
and Controls
Diagnostic message num‐
ber
A0000
A0001
A0002
A0003
A0012
A0013
A0500
A0501
A0502
A0503
A0510
297/369
Operation and Diagnosis
Diagnostic message
Communication phase 0
Communication phase 1
Communication phase 2
Communication phase 3
Control and power sections
ready for operation
Ready for power on
Supply module in voltage
control
Supply module in current
control
Supply module in operation
DC bus charging active
Test run for voltage control