Scope Of Supply; Technical Data; Ambient And Operating Conditions - Bosch Rexroth IndraDrive HMV Project Planning Manual

Supply units and power sections
Table of Contents

Advertisement

34/369
Bosch Rexroth AG | Electric Drives
Power Sections for Converters - IndraDrive C
Type Plate
5.2.3

Scope of Supply

5.2.4

Technical Data

Ambient and Operating Conditions

Description
Suitable for use on a circuit capable
of delivering not more than this
SCCR, symmetrical amperes (UL)
1)
rated input voltage, power (UL)
rated input current (UL)
3)
and Controls
1
device type
2
part number
3
serial number
4
bar code
5
country of manufacture
6
production week, 04W12 meaning year 2004, week 12
7
hardware index
Fig.5-12:
Type plate - power section (example of an HCS02 power section)
The scope of supply includes:
1 × touch guard
1 × connector X3, X5, X6, X13, X9 each (for designs W0054 and W0070)
1 × brochure with safety instructions (in 5 languages)
General Information
Conditions for transport and storage: see chapter
page
19.
Installation conditions: see chapter
This chapter contains:
limit values for use in the scope of C-UL
applied standards (CE conformity, UL listing)
UL Data
Ambient and operating conditions - UL ratings
HCS02.1E-
Symbol
Unit
W0012-_-03
I
A rms
SCCR
U
V
2)
LN_nenn
I
A
L_cont
Rexroth IndraDrive | Project Planning Manual
4.3 Installation Conditions , page
HCS02.1E-
W0028-_-03
42000
200...500
10,0
16,0
4.2 Transport and Storage,
19.
HCS02.1E-
HCS02.1E-
W0054-_-03
W0070-_-03
20,0
32,0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents