Bosch Rexroth IndraDrive HMV Project Planning Manual page 240

Supply units and power sections
Table of Contents

Advertisement

230/369
Bosch Rexroth AG | Electric Drives
IndraDrive M Supply Units
Description
rated control voltage input (UL)
control voltage when using motor
holding brake with motor cable
length < 50 m
2)
control voltage when using motor
holding brake with motor cable
length > 50 m
3)
maximum allowed voltage for 1 m
maximum inrush current at 24V
supply
pulse width of I
EIN3
input capacitance
rated power consumption control
voltage input at U
(UL)
4)
N3
Description
input frequency (UL)
tolerance input frequency (UL)
maximum allowed mains frequen‐
cy change
rotary field condition
Suitable for use on a circuit capable
of delivering not more than this
SCCR, symmetrical amperes (UL)
1)
nominal mains voltage
mains voltage three-phase at TN S,
TN C, TT mains
mains voltage three-phase at IT
mains
2)
mains voltage three-phase at Cor‐
ner-grounded-Delta mains
3)
tolerance U
(UL)
LN
and Controls
Control Voltage
Data for control voltage supply
Symbol
Unit
U
V
1)
N3
U
V
N3
U
V
N3
U
V
N3_max
I
A
EIN3_max
t
ms
EIN3Lade
C
mF
N3
P
W
N3
1) 2) 3)
observe supply voltage for motor holding brakes
4)
HMS, HMD, HCS: plus holding brake and control section; KCU01: at
max. number of axes; KSM01: plus holding brake (UN x IN)
Fig.7-58:
HMV - Data for control voltage supply
Mains Voltage
Data for mains voltage supply
Symbol
Unit
f
Hz
LN
Hz
Δf
/Δt
Hz/s
LN
I
A rms
SCCR
U
V
LN_nenn
U
V
LN
U
V
LN
U
V
LN
%
Rexroth IndraDrive | Project Planning Manual
HMV02.1R-W0015
24 ± 5 %
24 ± 5 %
26 ± 5 %
33,00
5,50
15
10,00
27
HMV02.1R-W0015
50...60
± 2
1
none
42000
3 AC 400
380...480
200...230
200...230
±10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents