Bosch Rexroth IndraDrive HMV Project Planning Manual page 187

Supply units and power sections
Table of Contents

Advertisement

Project Planning Manual | Rexroth IndraDrive
Description
maximum output current at
I
; f
= 12 kHz; t = 60 s;
out_base_5
s
T = 10 min; K = 1,1
19)
base load current at I
out_peak_5
f
= 12 kHz; t = 60 s; T = 10 min;
s
K = 1,1
maximum output current at
I
; f
= 16 kHz; t = 60 s;
out_base_5
s
T = 10 min; K = 1,1
20)
base load current at I
out_peak_5
f
= 16 kHz; t = 60 s; T = 10 min;
s
K = 1,1
Current Profile "UEL_I_e"
current profile "UEL_I_e"
Selecting Standard Motors
Symbol
Unit
I
A
out_peak5_12
;
I
A
out_base5_12
I
A
out_peak5_16
;
I
A
out_base5_16
1) 2) 3) 4) 5) 6)
see definition profile UEL_I_e
7) 8) 9) 10)
11) 12) 13)
14) 15) 16)
17) 18) 19)
20)
Fig.6-88:
HMD - Examples of allowed current profiles
The following current profiles have been defined for converters and inverters.
Profile
Fig.6-89:
Definition of current profiles
Operation With Standard Motors
General Information
The tables below show the nominal powers P
be operated at the respective drive controller. The data are subject to the fol‐
lowing conditions:
motor design:
4-pole standard motor (2 pole pairs) with rated voltage 3 AC 400 V, 50 Hz
at mains voltage U
4-pole standard motor (2 pole pairs) with rated voltage 3 AC 460 V, 60 Hz
at mains voltage U
Electric Drives
and Controls
Power Sections for Inverters - IndraDrive M
HMD01.1N-W0012
HMD01.1N-W0020
Explanation
The characteristic data of the profile are used to
select converters and inverters for operation with
standard motors and servo drives.
≥ 3 AC 400 V or
LN
≥ 3 AC 460 V
LN
| Bosch Rexroth AG
177/369
HMD01.1N-W0036
-
-
-
-
of standard motors which can
nenn

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents