Project Planning Manual | Rexroth IndraDrive
9
Touch Guard at Devices
9.1
Cutouts
WARNING
Type 1
Lethal electric shock caused by live parts with more than 50 V!
●
The appropriate touch guard must be mounted for each device following
connection work.
●
Never mount a damaged touch guard.
●
Immediately replace a damaged touch guard by an undamaged touch
guard.
●
Keep the cutouts at the touch guard as small as possible. Only remove
the cutouts if necessary.
Fig.9-1:
Cutouts at the touch guard
●
If the DC bus and the control voltage are connected by means of contact
bars, only cutout A may be removed from the touch guard.
●
If the DC bus and the control voltage are connected by means of cables
(e.g. in the case of multiple-line arrangement), the cutouts A, B and C may
be removed from the touch guard.
●
At the first and last device in a line of interconnected devices, you must
not remove any cutout at the outer side of the touch guard.
Electric Drives
| Bosch Rexroth AG
and Controls
Touch Guard at Devices
Type 2
291/369