Touch Guard At Devices; Cutouts - Bosch Rexroth IndraDrive HMV Project Planning Manual

Supply units and power sections
Table of Contents

Advertisement

Project Planning Manual | Rexroth IndraDrive
9

Touch Guard at Devices

9.1

Cutouts

WARNING
Type 1
Lethal electric shock caused by live parts with more than 50 V!
The appropriate touch guard must be mounted for each device following
connection work.
Never mount a damaged touch guard.
Immediately replace a damaged touch guard by an undamaged touch
guard.
Keep the cutouts at the touch guard as small as possible. Only remove
the cutouts if necessary.
Fig.9-1:
Cutouts at the touch guard
If the DC bus and the control voltage are connected by means of contact
bars, only cutout A may be removed from the touch guard.
If the DC bus and the control voltage are connected by means of cables
(e.g. in the case of multiple-line arrangement), the cutouts A, B and C may
be removed from the touch guard.
At the first and last device in a line of interconnected devices, you must
not remove any cutout at the outer side of the touch guard.
Electric Drives
| Bosch Rexroth AG
and Controls
Touch Guard at Devices
Type 2
291/369