Project Planning Manual | Rexroth IndraDrive
Control Voltage Block Diagram
The control voltage, which is supplied via the connection for 24V supply, takes
effect according to the following block diagram.
BR
circuit for brake control
LT
power section, e.g. HCS02
ST
control section, e.g CSB01
ZK
DC bus
int. SMPS
internal switching power supply unit, for types HCS0x.1E-Wxxxx-NxxV
Fig.4-13:
Block diagram of internal control voltage
Electric Drives
| Bosch Rexroth AG
and Controls
General Specifications of the Devices
25/369