Channel groups
The channels of SM 331; AI 8 x TC are arranged in four groups of two channels. You can
assign parameters only to one channel group.
The table below shows the relevant configuration of channel groups. The channel group
number is required to program SFC parameters in the user program.
Table 6- 28
Channels ...
Channel 0
Channel 1
Channel 2
Channel 3
Channel 4
Channel 5
Channel 6
Channel 7
6.10.2

Adjustable parameters

Introduction
For general information on programming analog modules, refer to the chapter Programming
analog modules (Page 294).
Parameters
Table 6- 29
Parameters of SM 331; AI 8 x TC
Parameters
Enable
Diagnostics interrupt
Process interrupt when limit
exceeded
Process interrupt at end of
cycle
Process interrupt trigger
High limit
Low limit
S7-300 Module data
Manual, 06/2017, A5E00105505-AJ
6.10 Analog input module SM 331; AI 8 x TC; (6ES7331-7PF11-0AB0)
Assignment of SM 331; AI 8 x TC channels to channel groups
... form one channel group each
Channel group 0
Channel group 1
Channel group 2
Channel group 3
Range of values
yes/no
yes/no
yes/no
32511 to -32512
from - 32512 to 32511
Default
Parameter
type
no
no
dynamic
no
32767
dynamic
-32768
Analog modules
Scope
Module
Channel