3.29 Digital output module SM 322; DO 8 x DC 24 V/ 0.5 A; with diagnostics interrupt; (6ES7322-8BF00-0AB0)
Technical specifications
Status, interrupts, diagnostics
Status display
Interrupts
•
Diagnostic interrupt
Diagnostic functions
•
Group error display
•
Channel error display (F)
•
Reading diagnostics data
Actuator selection data
Output voltage
•
"1" signal
without series diode
with series diode
Output current
•
"1" signal
Rated value
Permitted range
•
"0" signal (residual current)
Output delay (resistive load)
•
"0" to "1" transition
•
"1" to "0" transition
Load resistance range
Lamp load
Wiring two outputs in parallel
•
for redundant load control
•
for performance increase
Control of a digital input
Switching frequency
•
with resistive load
•
with inductive load to IEC 947-5-1, DC 13
•
with lamp load
Internal limiting of the inductive shutdown voltage to
Short-circuit protection of the output
•
Threshold
Wiring of the actuators
1) 5 mA to 0.6 A, with disabled wire-break monitoring
S7-300 Module data
Manual, 06/2017, A5E00105505-AJ
green LED per channel
programmable
programmable
red LED (SF)
red LED (F) per channel
supported
min. L + (- 0.8 V)
min. L+ (-1.6 V)
0.5 A
1)
10 mA to 0.6 A
max. 0.5 mA
max. 180 μs
max. 245 μs
48 Ω to 3 kΩ
max. 5 W
Only outputs with series diode and common refer-
ence potential
not supported
supported
1 binary input to IEC 61131, Type 2;
Type 1, with disabled wire-break monitoring
max. 100 Hz
max. 2 Hz
max. 10 Hz
typ. L + (-45 V)
yes, electronic
typ. 0.75 A to 1.5 A
using a 20-pin front connector
Digital modules