Parameter sets of signal modules
A.10 Setting of the analog input module SM 331; AI 8 x 16 Bit (6ES7331-7NF10-0AB0)
A.10
Setting of the analog input module SM 331; AI 8 x 16 Bit
(6ES7331-7NF10-0AB0)
Parameter
The table below contains all settings you can set for isolated digital output modules
SM 331; AI 8 ×16 Bit (6ES7331-7NF10-0AB0). This comparison shows which specific
method you can use to configure the various parameters:
● SFC55 "WR_PARM"
STEP 7
Parameters set in
Table A- 25
Parameters for the electrically isolated analog input module SM 331; AI 8 x 16 Bit
Parameters
Diagnostics: Group diagnostics
Diagnostics: with wirebreak monitor-
ing
Hardware interrupt when limit ex-
ceeded
Diagnostics interrupt enable
End-of-cycle alarm enable
Module operating mode
Noise suppression
Measuring method
Measuring range
Smoothing
High limit
Low limit
Note
To enable diagnostic interrupts in the user program at data record 1, you first need to enable
diagnostics at data record 0 in
560
programming device
STEP 7
can also be transferred to the module using SFC56 or SFC57.
Data record no.
Configurable using...
... SFC55
0
no
no
1
yes
yes
yes
128
yes
yes
yes
yes
yes
yes
yes
STEP 7
.
...Programming device
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
S7-300 Module data