Modbus Status and Fault Code Registers
The
following
table
provides
infom
1ation about the registers that
are
used to repo1t
status
and
fault
codes.
Each
of
these
registers
provides
inf 01mation
about a group of
status
codes
or
faults.
For
more
info1mation on
the
specific
faults that
can be
repo1
ted
for
each of
the fault
registers,
see
the troubleshooting info1mation for the inve1ter.
For
more inf01mation
about
the
status
codes, see
Table
6-20
on
page
6-27
and
Table
6-21
on
page
6-28.
Table 6-19.
Modbus status and fault code registers
Description
Start
End
No.
of
Mod bus
Data
Notes
Register
Register
Registers
Address
Type
Modbus base address
=
2000
Inve1ter
2100
2100
1
42101
UINT
See
Table
6-20
on
operating
page
6-27.
status
(state)
Main fault
2101
2101
1
42102
UINT
See
the fault
codes
descriptions
in the
inve1ter
troubleshooting
inf
01
mation.
Ddve fault
2102
2102
1
42103
UINT
See
the fault
codes
descriptions
in the
inve1ter
troubleshooting
inf
01
mation.
Voltage
fault
2103
2103
1
42104
UINT
See
the fault
codes
descriptions
in the
inve1ter
troubleshooting
inf
01
mation.
6-26
Data Monitoring
and
Controls
570-1001793-0SB