Download Print this page

Kenwood NX-5000 Series Function Reference page 130

Dmr func
Hide thumbs Also See for NX-5000 Series:

Advertisement

2 COMMUNICATIONS IN AN EMERGENCY
2.9 Placing the Transceiver in Emergency Mode by Using the Activity Detection Function
0
Configuring Activity Detection to be disabled
1
Do either of the following operations while Activity Detection is disabled:
0
Press the Activity Detection key.
0
Select a channel where Activity Detection is disabled.
0
Press the Menu key to enter Menu Mode, and select "Activity Detection" and then select "Off".
The "X" icon disappears and Activity Detection will be disabled.
If Activity Detection is disabled by using the Activity Detection key or
the Menu key, the Key Beep B (2 beeps) sounds from the transceiver.
Configuration using KPG-D1/ D1N
0
Assigning functions to the PF keys on the transceiver (
0
Configuring Activity Detection (DMR Conventional) to be enabled or disabled (Personality) (
Settings > Personal > Personality > DMR Conventional > General)
0
Configuring Activity Detection (DMR Conventional) to be enabled or disabled (Channel Edit) (
Settings > Zone/Channel > Channel Edit > DMR Conventional > General)
Man-down Detection
Man-down Detection is the function to place the transceiver automatically in Emergency Mode when the transceiver
becomes tilted and continues this position even after the time configured in Man-down Delay Time elapses.
Using this function, the transceiver can automatically enter Emergency Mode and notify a base station of the emergency
status when a user falls due to an accident.
If Man-down Pre-alert is configured, a Man-down Pre-alert (1 beep) sounds from the transceiver before the transceiver
enters Emergency Mode. The transceiver does not enter Emergency Mode if the transceiver returns from the tilted position
before the time configured in Man-down Delay Time elapses.
The threshold value of the tilt angle (Man-down Angle) to be used to detect that the transceiver is tilted can be configured
to 45 °, 60 °, or 75 °.
Note
Pressing the PTT switch while the time configured in Man-down Delay Time elapses pauses the Man-down Delay
0
Time count down. Releasing the PTT switch resumes the counting down.
Pressing the Activity Reset key resets the Man-down Delay Time timer and restarts counting down from the beginning.
0
Configuration using KPG-D1/ D1N
0
Configuring Man-down Detection to be enabled or disabled (
Information > Activity Detection)
0
Configuring Man-down Delay Time (
Detection)
0
Configuring Man-down Pre-alert to be enabled or disabled (
Information > Activity Detection)
0
Configuring Man-down Angle (
DMR FUNC (K, F)/Ver 2.20
Transceiver Settings > Key Assignment)
Transceiver Settings > Emergency > Emergency Information > Activity
Transceiver Settings > Emergency > Emergency Information > Activity Detection)
Z o n e 1
C h a n n e l 1
M en u
Transceiver Settings > Emergency > Emergency
Transceiver Settings > Emergency > Emergency
CONTENTS
A
12 : 34
M
Zo ne+
Transceiver
Transceiver
113
INDEX

Advertisement

loading

This manual is also suitable for: