2 COMMUNICATIONS IN AN EMERGENCY
2.7 Other Functions in Emergency Mode
Suspended Power-off
Suspended Power-off is the function to disable the transceiver to be turned off and retain the transceiver to be in Emergency
Mode even if the transceiver is operated to be turned off while in Emergency Mode.
For Mobile, the transceiver behavior varies as below depending on the configuration in Emergency Mode Type:
0
If "Silent" is configured in Emergency Mode Type:
The transceiver will not be turned off and remains in Emergency Mode even if the Power switch is pressed while the
transceiver is in Emergency Mode. In this case, the LCD is tuned off and the transceiver appears to be turned off. The
LED behaves according to the configuration in Emergency LED while Suspended Power-off is enabled.
0
If "Audible" is configured in Emergency Mode Type:
The transceiver will not be turned off and remains in Emergency Mode even if the Power switch is pressed while the
transceiver is in Emergency Mode. In this case, the LCD display does not change. The LED behaves according to the
configuration in Emergency LED while Suspended Power-off is enabled.
For Portable, the transceiver will not be turned off and remains in Emergency Mode even if the transceiver is operated to
be turned off while in Emergency Mode. In this case, the LCD display does not change. The LED behaves according to the
configuration in Emergency LED while Suspended Power-off is enabled.
If Suspended Power-off is enabled, the transceiver cannot be turned off until the transceiver exits Emergency Mode.
However, for Mobile, the transceiver can be turned off by pressing and holding the Power switch for 5 sec or more even
while Suspended Power-Off is activated.
Note
If Emergency Mode is activated by the Activity Detection function, Suspended Power-off does not function.
0
If Emergency Mode is activated by the Lone Worker function, Suspended Power-off functions.
0
Configuration using KPG-D1/ D1N
Configuring Suspended Power-off to be enabled or disabled (
Information)
DMR FUNC (K, F)/Ver 2.20