To arm the emulation analyzer on signal from
CMB
1 Enter the modify configuration command.
2 Answer "yes" to the "Modify interactive measurement specification?" question.
3 Answer "drive" to the "Should CMBT drive or receive Trig2?" question.
4 Answer "receive" to the "Should Analyzer drive or receive Trig2?" question.
5 Use the arm_trig2 option to the trace command.
To arm the emulation analyzer on signal from
BNC
1 Enter the modify configuration command.
2 Answer "yes" to the "Modify interactive measurement specification?" question.
3 Answer "drive" to the "Should BNC drive or receive Trig2?" question.
4 Answer "receive" to the "Should Analyzer drive or receive Trig2?" question.
5 Use the arm_trig2 option to the trace command.
Chapter 10: Making Coordinated Measurements
Using Trigger Signals
351