Ethernet Network Connection - Advanced Energy AE 75TX Installation And Operation Manual

Table of Contents

Advertisement

Advanced Energy
The prima1y purpose
of
the
commlmications
interface PCB is to provide
a
means
to
commllllicate with
the
inve1ter
through
either Modbus
RTU or
Modbus
TCP/IP.
These
connections can be
used for third party monit01ing
or
for
web-based inve1ter
monitoring through the AE
commercial
monito1ing website
(which uses
a proplietaiy
Ethernet
protocol).
The
communications
interface PCB provides the
following:
Remote disable
capabilities,
which allow
the
inve1
ter to
be disabled
through
external
methods such
as
an
e-stop,
generator
interlock,
or fire ala1m
panel
Binaiy
Modbus device
addressing
Additional
Modbus
slave po1t
tenninal
block,
which
makes it easier to nm an
RS-485 daisy-chain network
Inve1ters
with
the old
Comm
X PCB do not
suppo1
t the remote disable feature
or
other features
associated
with
the communications interface
PCB.
To detennine
whether
a
specific
inve1ter
has the communications interface
PCB,
visually
inspect
the commllllication board
in
the unit to
see
if the remote disable
te1minal block
is
present,
and the wire hainess
is
connected to the inve1ter
control
wire harness
connectors located at the edge of the
board.
&
DANGER:
Risk of electrical
shock.
High voltages are present in the inverter cabinet.
Both AC and DC disconnects must be in the OFF position when working on
the unit. Wait five minutes to discharge high voltage before opening the front
panels
of
the inverter.
&
DANGER:
Risque
d'electrocution.
L'interieur de l'onduleur est soumis
a
des hautes
tensions. Les interrupteurs de courant altematif et continu doivent etre mis
HORS TENSION durant les travaux sur
l'unite.
Attendez cinq minutes afin de
permettre la decharge du courant haute tension avant de demonter les
panneaux
avant de l'onduleur.
If
you
have
questions
about the capabilities of a specific
unit,
contact AE Solar
Energy Technical
Suppo1t.
Ethernet Network Connection
6-2
An
Ethernet connection
can be
used
to
connect
the unit to the
internet,
or to a
local
Modbus/TCP
network not connected to the internet. AE offers a free basic
monitoring
service
through
the solai·energy.advanced-energy.com
website.
Internet
service must
be
set
up
at
the installation site before the inve1ter
can
be accessed
online.
The data monitoring module
suppo1
ts only
hai·d-wired
CATS
solutions
to the
inve1ter. The module does
NOT
suppo1t wireless
configurations.
To access the data
Data Monitoring
and
Controls
570-1 001793-058