Advanced Energy AE 75TX Installation And Operation Manual page 125

Table of Contents

Advertisement

Advanced Energy®
AE
?STX and
AE
1
OOTX
Inverters
Temperature
Faults
The following
table
lists
the
temperanire faults.
All
temperanire faults may
be resolved
by:
Cleaning
all
the filters
Make sure air vents aren't blocked and sufficient space is provided around
all
air vents.
If the filters
are
clean
and
air flow is
insufficient,
contact AE
Solar
Energy Technical
Suppo1t.
Table 8-6.
Temperature (TMP) faults
Display Screen
Display Screen Text
Description
Hexadecimal
Value
0001
HEATSINK
TEMP Al
Module
heat-sink Al temperanire high
0002
HEATSINK
TEMP
A2
Module
heat-sink A2 temperanire high
0004
HEATSINK
TEMP Bl
Module
heat-sink B
1
temperamre high
0008
HEATSINK
TEMP
B2
Module
heat-sink B2 temperamre high
0010
HEATSINK
TEMP Cl
Module
heat-sink Cl temperamre high
0020
HEATSINK
TEMP
C2
Module
heat-sink C2 temperamre high
0040
BOARD
TEMP
HI
Control
board
temperanire high
0080
DRIVE TEMP
LOW
Drive
temperamre
low
0100
MAGNETICS
TEMP ID
Magnetics temperamre high
0200
AMBIENT TEMP
LOW
Ambient
temperamre
low
0400
MAG
TEMP
LOW
Magnetics temperamre low
0800
IPM
TEMPIDGH
IPM temperanire high
1000
INDUCTOR
TEMP
HIGH
Inductor temperamre high
System Faults
The
following
table lists the
system
faults.
Table
8-7. System (SYS) faults
Display
Display Screen
Text
Description
Action
Screen
Hex
Value
0001
GROUND
FAULT
Ground fault
CheckthePV
anay field
wiling.
570-1001793-0SB
Troubleshooting and Solar Energy
Technical
Support
8-11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ae 100tx

Table of Contents