3. Input module CPX-P-8DE-N-...
Byte 0 in PII
Byte 1 in PII
Process image outputs
PIO
Bit
Bit
Byte
7
6
0
For digital input channel operating mode (A) – channel 0 ... 7 (CH0 ... 7)
Tab. 3/7:
Process image outputs (PIO) - Standard process image
3-12
The signal states (0/1) of the digitised input signals are rep-
resented in byte 0 (
In the event of a short circuit or wire break the parameterised
replacement value is issued (
The module represents the diagnostic status of the 8 input
channels in byte 1 of the PII (
ates that there is a channel error at the corresponding input
(short circuit or wire break). A 0-signal indicates that the
input signal is in a signal range that is permissible for Namur
sensors.
Configuration of process image outputs (PIO)
The process image outputs (PIO) has 1 byte. In a standard
process image this range is reserved for future expansions.
Bit
Bit
Bit
5
4
3
Tab. 3/6).
Tab. 3/28 and Tab. 3/29).
Tab. 3/6). A 1-signal indic-
Bit
Bit
Bit
2
1
0
Festo P.BE-CPX-P-EA-EN en 1209NH English
Description
– Reserved

Advertisement