3. Input module CPX-P-8DE-N-...

3.2.2 Pin allocation CPX-P-8DE-N..

CPX-P-8DE-N.. with connection block CPX-P-AB-4xM12-4POL..
Connection block
1)
The screening (S) can be connected via the metal thread of the plug connector.
Tab. 3/3:
CPX-P-8DE-N.. with connection block CPX-P-AB-4xM12x-4POL..
Festo P.BE-CPX-P-EA-EN en 1209NH English
Pin assignment X1, X2
Socket X1:
1: BN+ [0]
2: BU– [0]
3: BN+ [1]
4: BU– [1]
1)
– : S
Socket X2:
1: BN+ [2]
2: BU– [2]
3: BN+ [3]
4: BU– [3]
1)
– : S
[...] = channel number ( [0] = channel 0, [1] = channel 1 etc.)
BN+ = input + (brown)
BU– = input – (blue)
S = screening
Use appropriate T-plug connectors or Duo plugs (plugs with
the possibility to connect two cables) to cost-effectively con-
nect two Namur sensors or contacts to one socket. Please
select the appropriate accessories from our catalogue
(
www.festo.com/catalogue).
LED
Pin assignment X3, X4
0
1
2
3
LED
Socket X3:
1: BN+ [4]
4
2: BU– [4]
3: BN+ [5]
5
4: BU– [5]
1)
– : S
Socket X4:
1: BN+ [6]
6
2: BU– [6]
3: BN+ [7]
7
4: BU– [7]
1)
– : S