Festo CPX-P-8DE-N Series Description page 30

Cpx terminal (-p) modules and connection blocks
Table of Contents

Advertisement

1. Overview and connection technology
1
Screwdriver,
blade
2.5 x 0.4 mm
2
Cable
3
Unlocking
4
Terminal opening
for inserting the
conductor
Fig. 1/4: Connecting and disconnecting the connecting cables
1-10
Connecting and disconnecting the conductor for spring-
loaded terminal blocks:
Note
The terminal will be damaged if a screwdriver is inserted
into the opening. Only insert conductors into the terminal
opening.
1. Use a screwdriver 1 to press and hold the release pin 3
(
Fig. 1/4). The terminal will then be unlocked.
2. Insert the wire of the cable into the terminal opening 4
as far as possible.
3. Release the pressure exerted on the release pin. This
securely clamps the wire in place.
1
2
Festo P.BE-CPX-P-EA-EN en 1209NH English
1
3
4