6. Function blocks
6.1 Manufacturer function blocks
400
Enter the function block settings here. The display contains the following elements:
BT07 block transfer Function block: block transfer, number 07
INI
Operating mode: INI - Initialize
+
Parameter set can be called via the PARAMETERS menu
>I1
Start address of source range or initialization markers (MB,MW,MD)
>I2
Start address destination range
>NO
Number of elements to be written in bytes per range, number: 1...383
Example of a block transfer function block when using the EDP programming lan-
guage
The trigger coil is connected to a device input.
I 05-----------------------------Ä BT07T_
Figure 193: Wiring the trigger coil
BT07E1o
BT07E2s
BT07E3--------------------------Ä M 42
Figure 194: Wiring the contacts
The messages of the function block are sent as a group message to a marker M42.
See also
→ Section "BC - Block compare", page 388
→ Section "BT - Block transfer", page 395
→ Section "MX - Data multiplexer", page 406
→ Section "SR - Shift register", page 415
→ Section "TB - Table function", page 423
→ Section "RE - Recipe records ", page 410
→ Section "Retention function", page 578
→ Section "Organizing marker ranges", page 202