Eaton easyE4 Manual page 239

Hide thumbs Also See for easyE4:
Table of Contents

Advertisement

6. Function blocks
6.1 Manufacturer function blocks
Example 3: Select day ranges
The year time switch HY01 is required to switch on at 00:00 on day 1 of each month and
switch off at 00:00 on day 29 of each month.
The HY year time switch must be assigned the following parameters:
Programming view/HY01/Year time switch parameters tab
Figure 126: Entry screen in the programming software
Example 4: Select "public holidays"
The year time switch HY01 is required to switch on at 00:00 on day 25.12 of each year
and switch off at 00:00 on day 28.12 of each year.
The HY year time switch must be assigned the following parameters:
Programming view/HY01/Year time switch parameters tab
Figure 127: Entry screen in the programming software
easyE4 10/19 MN050009 EN www.eaton.com