Eaton easyE4 Manual page 243

Hide thumbs Also See for easyE4:
Table of Contents

Advertisement

The function block and its parameters
Function block inputs
Description
(Bit)
EN
1: Activates the function block.
RE
Reset
1: Resets the actual counter value back to zero.
D_
Count direction
1: down counting
0: up counting
SE
When there is a rising edge at SE, the value at
SV is applied as the operating hours value and
appears at QV
(DWord)
I1
The value at I1 is the reference value. If this ref-
erence value is greater than the operating hours
value, output Q1 will be set.
SV
When there is a rising edge at SE, the value at
SV is applied as the operating hours value
Assigning operands
You can assign the following operands to the function block inputs that are numeric
inputs.
Operators
1)
Constant, timer constant
MD, MW, MB - Markers
NB, NW, ND - NET markers
nNB, nND, nND- NET markers
NET station n
IA - Analog input
QA - Analog output
QV - QV - Numeric output of a FB
1) Only on function blocks T, AC
2) Only on projects with ≥ 2 base devices on NET
You can assign the following operands to the function block inputs that are bit inputs:
Operators
Constant 0, constant 1
M – Markers
2)
RN - Input bit via NET
SN - Output bit via NET (send)
2)
N - Net marker bit
2)
nN - NET marker bit
NET station n
easyE4 10/19 MN050009 EN www.eaton.com
Value inputs
x
x
2)
x
2)
x
x
x
x
Bit inputs
x
x
x
2)
x
x
x
6. Function blocks
6.1 Manufacturer function blocks
Note
Integer value range:
0...596 523
239