Mounting and Operating Instructions
Fire-Resistant Cabinet Type DualGuard-S ESF30
Mounting and Operating Instructions
Fire-Resistant Cabinet Type DualGuard-S ESF30
Target group: qualified electricians according to DIN VDE 0105 Part 1

Advertisement

Table of Contents
loading

Summary of Contents for Eaton DualGuard-S ESF30 Series

  • Page 1 Mounting and Operating Instructions Fire-Resistant Cabinet Type DualGuard-S ESF30 Mounting and Operating Instructions Fire-Resistant Cabinet Type DualGuard-S ESF30 Target group: qualified electricians according to DIN VDE 0105 Part 1...
  • Page 2: Table Of Contents

    Content 1 Important information . . . . . . . . . . . . . . . . . . .3 5 Transport .
  • Page 3: Important Information

    1 Important information 1 Important information NOTE: Provides important tips and pointers on procedures, or for handling the described equipment or plant components. 1.1 General ATTENTION! Mounting work must always be performed by qualified electricians (also refer to DIN VDE 0105 Part 1, the German Calls attention to hazards that can cause damage to equip- Accident Prevention Regulations in BGV A3 issued by the ment or plant components, or can result in environmental...
  • Page 4: Liability, Warranty, And Transfer Of Custody Declaration

    2 Safety 1.5 Liability, warranty, and transfer of custo- 1.8 Disposal dy declaration Unless a return or disposal agreement was concluded, dis- mantled components must be recycled after having been • In order to ensure optimum functionality of our products, properly disassembled.
  • Page 5: Contents Of The Mounting And Installation Instructions

    2 Safety 2.2 Contents of the mounting and installation 2.5 Personnel requirements instructions Only authorised and qualified personnel may carry out work on or with the device. These personnel must have Any person authorised to carry out work on or with the been trained in possible hazards that may occur.
  • Page 6: Layout

    4 Layout 4 Layout 4.1.2 Dimensioned drawings DualGuard-S ESF30 30P 4.1 DualGuard-S ESF30 30P 4.1.1 Components DualGuard-S ESF30 30P 918 36,14 Terminal block Thermostatic control / temperature exceeded Thermostatic control of internal temperature Control module ACU Thermostatic control of external temperature Circuit switch-overs SKU.1 CG-S 3-PM-IO module...
  • Page 7: Dualguard-S Esf30 15P

    4 Layout 4.2 DualGuard-S ESF30 15P 4.2.2 Dimensioned drawings DualGuard-S ESF30 15P 4.2.1 Components DualGuard-S ESF30 15P Terminal block Control module ACU Thermostatic control of internal temperaturer Circuit switch-overs SKU.1 CG-S 3-PM-IO module Thermostatic control / temperature exceeded Mounting and Operating Instructions Fire-Resistant Cabinet Type DualGuard-S ESF30 January 2021 www.ceag.de...
  • Page 8: Dualguard-S Esf30 Sou5

    4 Layout 4.3 DualGuard-S ESF30 SOU5 4.4 DualGuard-S ESF30 SOU3 4.3.1 Components DualGuard-S ESF30 SOU5 4.4.1 Components DualGuard-S ESF30 SOU3 Enclosure Circuit modules SOU CG-S 2 x 4 A Enclosure Circuit modules SOU CG-S 2 x 4 A 4.3.2 Dimensioned drawings DualGuard-S 4.4.2 Dimensioned drawings DualGuard-S ESF30 SOU5 ESF30 SOU3...
  • Page 9: Dualguard-S Esf30 Sou2

    4 Layout 4.5 DualGuard-S ESF30 SOU2 4.6 DualGuard-S ESF30 SOU1 4.5.1 Components DualGuard-S ESF30 SOU2 4.6.1 Components DualGuard-S ESF30 SOU1 Enclosure Circuit module SOU CG-S 2 x 4 A Enclosure Circuit modules SOU CG-S 2 x 4 A 4.5.2 Dimensioned drawings DualGuard-S 4.6.2 Dimensioned drawings DualGuard-S ESF30 SOU2 ESF30 SOU1...
  • Page 10: Transport

    5 Transport 5 Transport ATTENTION! Any damage to the equipment must be immediately reported to us in writing! 5.1 Brief notes about important transport considerations The recipient is responsible for the receiving inspection The shipped product and its packaging must be promptly inspected for damage, completeness, and other anomalies.
  • Page 11: Instructions For Unhinging The Doors

    6 Assembly/installation DualGuard-S ESF30 28-P and 13-P 6.3 Instructions for unhinging the doors 6.6 EHL/ESL wall fixing The doors are unhinged by pushing the pins from the leafs. For safety reasons, the door panels should always be un- hinged by at least 2 persons. 6.4 Fixing the hanging brackets onto the rear of the enclosure •...
  • Page 12: Setup Conditions For Fire Protection Enclosures

    5 Transport 6.8 Setup conditions for fire protection en- technical safety inspection can only be performed with the required care by a qualified employee, since this requires closures sufficient experienced and extensive knowledge. • Conventional, mild household cleaning agents can be used •...
  • Page 13: Cable Routing In The Distribution Cabinet

    7 Dismantling of the fan unit 6.12 Cable routing in the distribution cabinet 6.13 Pedestal installation • Pre-drill the point where the cable is to be inserted accor- Install the pedestal of the ES enclosure in a manner that ding to the cable diameter. Observe internal insulation, locates the ventilation gap above the pedestal rail (Figure 6).
  • Page 14 7 Dismantling of the fan unit WARNING 230 V AC Dangerous Voltage. Can cause death, heavy injuries and property damage! 2. Disconnect and remove the temperature sensor. Loosen the cable connection at the contacts of the termi- nal block. Pull out the temperature-sensor with cable out of the enclosure.
  • Page 15: Ventilation Diagram

    8 Ventilation diagram 8 Ventilation diagram ATTENTION! The black compriband is part of the ventilation system and ensures, among other things, that only the „fresh“ supply air comes from below at the lower/rear side. This band must not be removed. EXHAUST AIR SUPPLY AIR Schematic diagram of the ventilation...
  • Page 16: Ventilation Unit: Technical Data

    10 Ventilation unit: technical data 10 Ventilation unit: technical data Power supply Operating voltage 185…230…245V/AC 50Hz Electricity consumption 0.15A Power Speed 2850 min-1 Air flow 164m³/h Static pressure 8.64mmH2O Noise level 45 dB(A) Operating temperature -10…70°C Thermal fuse Protection level 77°C Smoke detector Light alarm...
  • Page 17: Connection Plan

    11 Connection plan 11 Connection plan WARNING 230V AC ATTENTION Dangerous Voltage. May cause death heavy body injuries Danger caused by electrical voltage and property damage. Disconnect all poles of the device before starting to dismantle or changing the composition. Follow the instructions of VDE 0100 for 230 V main supply.
  • Page 18: Setup And Installation Dualguard-S Esf30

    9 Setup and installation DualGuard-S ESF30 SOU5, SOU3, SOU2, SOU1 9 Setup and installation DualGuard-S ESF30 SOU5, SOU3, SOU2, SOU1 9.1 Wall-mounted installation The unit is mounted with the included anchor screws, rated Only the dowels or anchor screws described in the "General for concrete walls at strength class C20/25 to C50/60 or ma- construction code approval"...
  • Page 19: Notes

    Notes Notes Mounting and Operating Instructions Fire-Resistant Cabinet Type DualGuard-S ESF30 January 2021 www.ceag.de...
  • Page 20 The aim of Eaton is to provide a reliable, efficient and safe power supply where it is needed most. Eaton's experts have comprehensive in-depth specialist knowledge in the area of energy management in the most diverse of sectors and therefore they are able to provide customer-specific, integrat- ed solutions to meet the most challenging demands of its customers.