Defined values
<time>
String type value; format is "yy/MM/dd,hh:mm:ss±zz", where characters indicate year (two last
digits), month, day, hour, minutes, seconds and time zone (indicates the difference, expressed in
quarters of an hour, between the local time and GMT; three last digits are mandatory, range
-47...+48). E.g. 6
NOTE: 1. Time zone is nonvolatile, and the factory value is invalid time zone.
2. Command +CCLK? will return time zone when time zone is valid, and if time zone is
00, command +CCLK? will return "+00", but not "-00".
Examples
AT+CCLK="08/11/28,12:30:33+32"
OK
AT+CCLK?
+CCLK: "08/11/28,12:30:35+32"
OK
AT+CCLK="08/11/26,10:15:00"
OK
AT+CCLK?
+CCLK: "08/11/26,10:15:02+32"
OK
4.18
AT+CMEE Report mobile equipment error
Description
This command is used to disable or enable the use of result code "+CME ERROR: <err>" or
"+CMS ERROR: <err>" as an indication of an error relating to the functionality of ME; when
enabled, the format of
SIM PIN
References
NO
3GPP TS 27.007
Syntax
Test Command
AT+CMEE=?
Read Command
AT+CMEE?
Write Command
SIM7500_SIM7600 Series_AT Command Manual_V1.07
th
of May 2008, 14:28:10 GMT+8 equals to "08/05/06,14:28:10+32".
<err>
can be set to numeric or verbose string.
Responses
+CMEE: (list of supported <n>s)
OK
Responses
+CMEE:
<n>
OK
Responses