10.3
AT+CVAUXV Set voltage value of the pin named VREG_AUX1
Description
This command is used to set the voltage value of the pin which is named VREG_AUX1.
SIM PIN
References
NO
Vendor
Syntax
Test Command
AT+CVAUXV=?
Read Command
AT+CVAUXV?
Write Command
AT+CVAUXV=<voltage>
Defined values
<voltage>
Voltage value of the pin which is named VREG_AUX1. The unit is in mV. And the value must the
multiple of 50mv.
Examples
AT+CVAUXV=?
+CVAUXV: (1700-3050)
OK
AT+CVAUXV=2800
OK
AT+CVAUXV?
+CVAUXV: 2800
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
Responses
+CVAUXV: (list of supported <voltage>s)
OK
Responses
+CVAUXV:
<voltage>
OK
Responses
OK
ERROR