a numeric parameter which indicates whether show the prompt of where the data received or not
before received data.
0 –
do not show the prompt
1 –
show the prompt,the format is as follows:
"RECV
Examples
AT+CIPSRIP=?
+CIPSRIP: (0-1)
OK
AT+CIPSRIP=1
OK
AT+CIPMODE Select TCP/IP application mode
15.2.6
Description
This command is used to select transparent mode (data mode) or non-transparent mode (command
mode ).The default mode is non-transparent mode.
SIM PIN
References
NO
Vendor
Syntax
Test Command
AT+CIPMODE=?
Read Command
AT+CIPMODE?
Write Command
AT+CIPMODE=<mode>
Execution Command
AT+CIPMODE
Defined values
<mode>
0 – Non transparent mode
SIM7500_SIM7600 Series_AT Command Manual_V1.07
FROM:<IP
ADDRESS>:<PORT>"
Responses
+CIPMODE: (list of supported <mode>s)
OK
Responses
+CIPMODE:
<mode>
OK
Responses
OK
ERROR
Responses
Set default value
<mode>=0
(
OK
Smart Machine Smart Decision
:
)