Execution Command
AT+CPAS
Defined values
<pas>
0 – ready (ME allows commands from TA/TE)
3 – ringing (ME is ready for commands from TA/TE, but the ringer is active)
4 – call in progress (ME is ready for commands from TA/TE, but a call is in progress)
Examples
RING
(with incoming call)
AT+CPAS
+CPAS: 3
OK
AT+CPAS=?
+CPAS: (0,3,4)
OK
4.20

AT+SIMEI Set IMEI for the module

Description
This command is used to set the module's IMEI value.
SIM PIN
References
NO
Vendor
Syntax
Test Command
AT+SIMEI=?
Read Command
AT+SIMEI?
Write Command
AT+SIMEI=<imei>
Defined values
SIM7500_SIM7600 Series_AT Command Manual_V1.07
Responses
+CPAS:
<pas>
OK
Responses
OK
Responses
+SIMEI:
<imei>
OK
Responses
OK