12 AT Commands for Hardware
12.1
AT+IPREX Set local baud rate permanently
Description
This command sets the baud rate of module's serial interface permanently, after reboot the baud rate
is also valid, if set to 0, then support autobaud, and the value of the IPR will be changed to current
baudrate when the autobaud is successful.
SIM PIN
References
NO
Vendor
Syntax
Test Command
AT+IPREX=?
Read Command
AT+IPREX?
Write Command
AT+IPREX=<speed>
Execution Command
AT+IPREX
Defined values
<speed>
Baud rate per second:
0, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400, 460800, 921600,
3000000, 3200000, 3686400
Examples
AT+IPREX?
+IPREX: 115200
OK
AT+IPREX=?
SIM7500_SIM7600 Series_AT Command Manual_V1.07
Responses
+IPREX: (list of supported<speed>s)
OK
Responses
+IPREX:
<speed>
OK
Responses
OK
ERROR
Responses
Set default value 115200:
OK
Smart Machine Smart Decision
246
2017-12-25
Need help?