At+Ctzr Time And Time Zone Reporting - SimCom SIM7500 Series At Command Manual

Hide thumbs Also See for SIM7500 Series:
Table of Contents

Advertisement

Examples
AT+CTZU?
+CTZU: 0
OK
AT+CTZU=1
OK
5.18

AT+CTZR Time and time zone reporting

Description
This command is used to enable and disable the time zone change event reporting. If the reporting
is enabled the MT returns the unsolicited result code +CTZV: <tz>[,<time>][,<dst>]whenever the
time zone is changed.
NOTE: The time zone reporting is not affected by the Automatic Time and Time Zone command
AT+CTZU.
SIM PIN
References
YES
3GPP TS 27.007
Syntax
Test Command
AT+CTZR=?
Read Command
AT+CTZR?
Write Command
AT+CTZR=< on/off >
Execution Command
AT+CTZR
Defined values
<on/off>
Integer type value indicating:
0 – Disable time zone change event reporting (default).
1 – Enable time zone change event reporting.
+CTZV: <tz>[,<time>][,<dst>]
Unsolicited result code when time zone received from network isn't equal to local time zone, and if
SIM7500_SIM7600 Series_AT Command Manual_V1.07
Responses
+CTZR: (list of supported
OK
Responses
+CTZR:
< on/off >
OK
Responses
OK
ERROR
Responses
Set default value:
OK
Smart Machine Smart Decision
< on/off
>s)
105
2017-12-25