SimCom SIM7500 Series At Command Manual page 13

Hide thumbs Also See for SIM7500 Series:
Table of Contents

Advertisement

9.3
AT+CGACT PDP context activate or deactivate ............................................................................. 195
9.4
AT+CGDCONT Define PDP context .............................................................................................. 196
9.5
AT+CGDSCONT Define Secondary PDP Context ......................................................................... 198
9.6
AT+CGTFT Traffic Flow Template ................................................................................................ 201
9.7
AT+CGQREQ Quality of service profile (requested) ..................................................................... 204
9.8
AT+CGEQREQ 3G quality of service profile (requested) .............................................................. 206
9.9
AT+CGQMIN Quality of service profile (minimum acceptable) ..................................................... 211
9.10
AT+CGEQMIN 3G quality of service profile (minimum acceptable) ............................................ 214
9.11
AT+CGDATA Enter data state ......................................................................................................... 218
9.12
AT+CGPADDR Show PDP address ................................................................................................ 219
9.13
9.14
AT+CGEREP GPRS event reporting .............................................................................................. 222
9.15
10
Hardware Related Commands ................................................................................................. 226
10.1
AT+CVALARM Low and high voltage Alarm ................................................................................ 226
10.2
AT+CVAUXS Set state of the pin named VREG_AUX1 ............................................................... 227
10.3
AT+CVAUXV Set voltage value of the pin named VREG_AUX1 ................................................. 228
10.4
AT+CADC Read ADC value ........................................................................................................... 229
10.5
AT+CADC2 Read ADC2 value ....................................................................................................... 229
10.6
critical temperature ......................................................................................................................................... 230
10.7
AT+CPMVT Low and high voltage Power Off ............................................................................... 232
10.8
AT+CDELTA Set the module go to recovery mode ........................................................................ 233
10.9
AT+CRIIC Read values from register of IIC device ....................................................................... 233
10.10 AT+CWIIC Write values to register of IIC device .......................................................................... 234
10.11 AT+CBC Read the voltage value of the power supply .................................................................... 235
10.12 AT+CPMUTEMP Read the temperature of the module .................................................................. 235
11
AT Commands for SIM Application Toolkit ............................................................................ 237
11.1
AT+STIN SAT Indication ................................................................................................................ 237
11.2
AT+STGI Get SAT information ...................................................................................................... 238
11.3
AT+STGR SAT respond .................................................................................................................. 241
11.4
AT+STK STK switch ...................................................................................................................... 242
11.5
AT+STKFMT Set STK pdu format ................................................................................................. 243
11.6
AT+STENV Original STK PDU Envelope Command .................................................................... 244
11.7
AT+STSM Get STK Setup Menu List with PDU Mode ................................................................. 245
12
AT Commands for Hardware ................................................................................................... 246
12.1
AT+IPREX Set local baud rate permanently ................................................................................... 246
12.2
AT+CFGRI Indicate RI when using URC ....................................................................................... 247
12.3
AT+CSCLK Control UART Sleep ..................................................................................................... 248
12.4
AT+CMUX Enable the multiplexer over the UART ....................................................................... 249
12.5
AT+CGFUNC Enable/disable the function for the special GPIO ...................................................... 250
12.6
AT+CGDRT Set the direction of specified GPIO............................................................................ 252
12.7
AT+CGSETV Set the value of specified GPIO ............................................................................... 253
SIM7500_SIM7600 Series_AT Command Manual_V1.07
GPRS mobile station class .................................................................................. 221
Smart Machine Smart Decision
12
2017-12-25

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SIM7500 Series and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Sim7600 series

Table of Contents

Save PDF