Belt Cleaner Section - MINOLTA-QMS Magicolor 2200 Series Manual

Hide thumbs Also See for Magicolor 2200 Series:
Table of Contents

Advertisement

2. Remove the image transfer roller pressure sensor
3. Remove the suction fan motor
4. Remove the transport paper sensor

3-18 Belt cleaner section

1. Remove the upper-right reinforcement plate
1. Remove the transport cover (or duplex cover if installed) by remov-
ing two screws.
2. Remove the tabs for the image transfer roller pressure sensor.
(There is 1 connector and no screws.)
1. Remove the transport cover (or duplex cover if installed) by remov-
ing two screws.
2. Remove the 2 set screws for the suction fan. (There are 3 harness
saddles and 1 connector.)
1. Remove the transport cover (or duplex cover if installed) by remov-
ing two screws.
2. Remove the suction fan.
3. Remove the transfer roller.
4. Remove the transfer roller pressure shaft by removing 1 clip and
two screws. Be careful when removing this shaft because it also
serves to secure the spring loaded transfer roller housing.
5. Remove the topmost paper guide (2 clips)
6. Remove the 1 set screw for the transport paper sensor and 1 con-
nector.
1. Remove the rear cover.
2. Remove the left-rear cover.
3. Remove the right-rear 1 cover.
4. Remove the right-rear 2 cover.
5. Remove the top cover.
6. Remove the 5 screws for the upper-right reinforcement plate.
D-20