3-19 Fusing section

1. Remove the pressure roller release sensor

3-20 Paper exit section

1. Remove the paper exit section

3-21 Duplex unit section

1. Remove the duplex paper-detecting sensor
Sensor cover
2. Remove the duplex unit circuit board cover
1. Remove the fusing pressure motor. ( Refer to Section 3-7)
2. Remove the 1 connector for the pressure roller release sensor and
the 1 set screw.
1. Open the fusing cover.
2. Remove the 4 screws for the sensor protection plate and remove it.
3. Remove the 1 connector for the paper exit section and remove the
hooks.
1. Remove the 2 screws for the duplex unit and remove it from the
main printer unit.
2. Remove the sensor cover.
3. Remove the stopper for the duplex paper-detecting sensor.
(There is 1 connector.)
1. Remove the circuit board cover. (There is 1 screw.)