4. Remove the rack home position sensor for black toner
Rack home position sensor
for black toner
5. Remove the developing motor assembly
Spring
6. Remove the toner cartridge rack
1. Remove the rear cover.
2. Remove the left-rear cover.
3. Remove the right-rear cover 1.
4. Remove the right-rear cover 2.
5. Remove PWB-A mounting plate with the PWB-A attached.
6. Remove HV1 mounting plate with HV1 attached.
7. Remove the 1 set screw for the rack home position sensor for black
toner and the 1 connector to remove the sensor.
1. Remove the controller cover.
2. Remove the rear cover.
3. Remove PU1 together with its mounting plate.
4. Remove the 1 connector for the developing motor assembly and the
4 set screws (tension screws). (There is 1 spring and 4 harness
clamps.)
1 Remove the rear cover.
2. Remove the left-rear cover.
3. Remove the right-rear cover 1.
4. Remove the right-rear cover 2.
5. Remove the upper cover.
6. Remove PWB-A mounting bracket with PWB-1 and HV2 attached.
7. Remove the upper-right reinforcement plate.
8. Remove the left frame plate.
9. Remove the 3 connectors for the rear rack bearing and the 4 set
screws.
10. Carefully remove the front and rear bearings.
11. Push the rack release button from the front surface. (Remove the E-
rings for the rack release lever and free the lever.)
Rack
12. Bring the rack to the front and remove it, using care not to catch the
release
piece on the end.