5-3-3 Service Call 0E SUCTION FAN (Suction fan motor error
No.
1.
Does the suction fan motor (M7) operate during
power on initialization?
Others
The suction motor (M7) operates at two speeds: full speed and half speed.
• When the fan motor is starting, when the cover is closed, when the pause mode has ended: Full speed for 2 seconds
and half speed afterward.
• During transport motor (M1) operation: full speed
• During transport motor (M1) stop: half speed
• Cover open: stop
• Others: Half speed
A suction fan motor error is detected when the suction fan lock signal is active for 0.5 seconds.
Fan motor operation
Transport motor
M7 Full
Check
ON
OFF
Full speed
Half speed
Result
No
Ensure the connection of the connector
(PJ3A) is secure.
Replace fan motor.
Replace PWB-A
E-19
)
Corrective action