Image Troubleshooting - MINOLTA-QMS Magicolor 2200 Series Manual

Hide thumbs Also See for Magicolor 2200 Series:
Table of Contents

Advertisement

7

Image troubleshooting

Image defect
No image
Completely black image
ABCDE
ABCDE
ABCDE
ABCDE
White spots/ Black spots
ABCDE
ABCDE
ABCDE
ABCDE
Toner smudges on back side
Cause
OHP selected but ordinary plain
paper used.
Defective bias contact (T/C).
Bad connection (image transfer
roller).
Bad connector connection (laser
unit).
Defective data output.
Defective bias contact (D/C).
Defective charge (D/C).
Impurities in the toner cartridge.
Impurities in the OPC drum.
Impurities on the image transfer
belt.
Impurities on fusing belt.
Dirty paper transport passage.
Dirty image transfer roller.
Dirty fusing pressure roller.
E-36
Step
Set the correct driver.
Reset the toner cartridge. (If special color,
replace the toner cartridge.)
Reset the image transfer roller unit.
Ensure the connection of the connector
(PJ12A) is secure.
Replace the laser unit.
Replace HV1 (high voltage circuit board).
Replace the OPC drum
Replace HV1 (high voltage circuit board).
Replace the toner cartridge.
Replace the OPC drum.
Clean the image transfer belt.
Replace the image transfer belt.
Clean the fusing belt.
Replace the oil coating roller.
Replace the fusing unit.
Clean the paper transport passage.
Replace the image transfer roller unit.
Clean the pressure roller.
Replace the oil coating roller.

Advertisement

Table of Contents
loading

Table of Contents