3. Remove the paper empty sensor
3. Remove the paper pickup rollers

3-14 Transport section

1. Remove the timing roller solenoid
2. Remove the transport roller solenoid
1. Remove four hooks for the paper empty sensor and disconnect 1
connector.
2. Remove the sensor.
1. Slide paper pickup roller toward the front of the printer.
2. Remove the roller.
1. Remove the rear cover.
2. Remove the left-rear cover.
3. Remove the right-rear 1 cover.
4. Remove the right-rear 2 cover.
5. Remove the 4 screws for the mounting plate for PU1 (power supply
circuit board) and remove the mounting plate together with PU1.
6. Remove the 1 set screw for timing roller solenoid connector. (There
is 1 harness clamp.)
1. Remove the rear cover.
2. Remove the left-rear cover.
3. Remove the right-rear 1 cover.
4. Remove the right-rear 2 cover.
5. Remove the PWB-A mounting plate together with the PWB-A
attached.
6. Remove the 1 set screw for the transport roller solenoid connector.