5-11 Memory errors

There are four memory errors.
5-11-1 Service Call 29 MEM MALF COUNTER
No.
1.
Cycle the power switch on and off. Does the error
reoccur?
5-11-2 Service Call 2A MEM MALF DATA
No.
1.
Cycle the power switch on and off. Does the error
reoccur?
5-11-3 Service Call 2B MEM MALF ACCESS
No.
1.
Cycle the power switch on and off. Does the error
reoccur?
5-11-4 Service Call 2C MEM MALF INSTALL
No.
1.
Cycle the power switch on and off. Does the error
reoccur?
2.
Are any discrepancies found with the wiring?
5-12 Service Call 04 MAIN UNIT
No.
1.
Cycle the power switch on and off. Does the error
reoccur?
5-13 Service Call 05 FLASH ROM
No.
1.
Cycle the power switch on and off. Does the error
reoccur?
Check
Check
Check
Check
Check
Check
E-31
Result
Corrective action
Yes
Replace the PWB-A.
Result
Corrective action
Yes
Replace the PWB-A.
Result
Corrective action
Yes
Replace the PWB-A.
Result
Corrective action
Yes
Inspect associated wiring between the
memory board and PWB-A.
Yes
Repair as needed.
No
Replace the PWB-A.
Result
Corrective action
Yes
Replace the PWB-A.
Result
Corrective action
Yes
Replace the PWB-A.