5-3-4 Service Call 0B XFER FAN BELT (Toner suction fan motor error
No.
1.
Does the toner suction fan motor (M11) operate
during power on initialization? (Place your hand
over the fan exhaust port and feel for air move-
ment to check.)
Others
The toner suction fan motor (M11) normally operates when the transport motor (M1) is in operation.
• During transport motor (M1) operation: Full speed
• Cover open: stop
A toner suction fan motor error is detected when the toner suction fan lock signal is active for 0.5 seconds.
Fan motor operation
Transport motor
M11 Full
Check
ON
OFF
Full speed
OFF
Result
No
Ensure the connection of the connector
(PJ30A) is secure.
Replace fan motor.
Replace PWB-A
E-20
)
Corrective action