Access to link devices
Access from a user program to link devices (RX, RY, RWr, RWw, SB, and SW) of this product is possible.
Access method
Use C Controller module dedicated functions and MELSEC data link functions to access link devices.
Access the device of the refresh target assigned by "Refresh Setting" using C Controller module dedicated
functions and MELSEC data link functions.
■Function list
Objective
Writing data to device
Writing data to device
(During interrupt)
Reading data from device
Reading data from device
(During interrupt)
For details on the C Controller module dedicated functions and MELSEC data link functions, refer to the following manual.
MELIPC MI5000 Series Programming Manual (Windows)
MELIPC MI5000 Series Programming Manual (VxWorks)
7 CC-Link IE Field Network Basic FUNCTION
84
7.1 Cyclic Transmission
Function name
CCPU_WriteDevice
mdDevRstEx
mdDevSetEx
mdRandWEx
mdSendEx
CCPU_WriteDevice_ISR
CCPU_ReadDevice
mdRandREx
mdReceiveEx
CCPU_ReadDevice_ISR
Description
Writes data to internal user devices and internal system devices of a
MELIPC.
Resets bit devices.
Sets bit devices.
Writes data by specifying a device type and a range to be written.
Writes data to devices in a batch.
Writes data to internal user devices and internal system devices of a
MELIPC.
Reads data from the internal user devices and internal system devices
of a MELIPC.
Reads data by specifying a device type and a range to be read.
Reads data from devices in a batch.
Reads data from the internal user devices and internal system devices
of a MELIPC.