Download Print this page

Mitsubishi Electric MELIPC MI5000 Series User Manual page 72

Hide thumbs Also See for MELIPC MI5000 Series:

Advertisement

■Method to select module in "Enable/Disable Ignore Station Errors" window
In the "Enable/Disable Ignore Station Errors" window, reserved station temporary error disabled stations settings of multiple
slave stations with a single operation is possible.
• Temporary error disabled station settings
• Temporary error disabled station settings/remove
■Stations that can not be set as temporary error disabled stations
Stations that are reserved station temporary clear stations cannot be set as temporary error disabled stations.
■If using in line connection
In the following cases, the stations sit in the error disabled station will not be detected as a data link abnormal station, however
other than the disconnected stations will become data link abnormal stations.
6 CC-Link IE Field Network FUNCTION
70
6.4 CC-Link IE Field Network diagnosis
1.
In the "CC-Link IE Field Diagnostics" window, click the
[Enable/Disable Ignore Station Errors] button.
2.
In the "Error disabled station list", click the station to be
set temporarily as an error disabled station. If clicked,
the station display changes to red letters on a yellow
background.
Only stations that are not set temporarily as an error disabled
stations can be selected. Stations that are not set temporarily
as an error disabled stations are displayed in white.
3.
Click the [Settings end] button to temporarily set as an
error disabled station.
1.
Displays the "Enable/Disable Ignore Station Errors"
windows in the same way as with the temporary error
disabled station settings.
2.
In the "Error disabled station list", click a station to clear
as a temporary error disabled station. If clicked, the
station display changes to red letters on a white
background.
Only temporary error disabled stations can be selected.
Temporary error disabled stations are displayed in yellow.
3.
Click the [Settings end] button to remove the temporarily
error disabled station settings.
Error invalid station
Not a data link faulty station
Error
Data link faulty stations

Advertisement

loading

This manual is also suitable for:

Melipc mi5122-vw