Download Print this page

Mitsubishi Electric MELIPC MI5000 Series User Manual page 246

Hide thumbs Also See for MELIPC MI5000 Series:

Advertisement

Error code
D216H to D217H
D218H
D219H
D21AH
D21BH to D21CH
D21DH
D21EH
D222H
D223H to D224H
D22EH
D22FH
D230H
D231H
APPX
244
Appendix 2 List of Error Codes
Error name
CC-Link IE Field Network function
related errors
CC-Link IE Field Network function
related errors
CC-Link IE Field Network function
related errors
CC-Link IE Field Network function
related errors
CC-Link IE Field Network function
related errors
CC-Link IE Field Network function
related errors
CC-Link IE Field Network function
related errors
CC-Link IE Field Network function
related errors
CC-Link IE Field Network function
related errors
CC-Link IE Field Network function
related errors
CC-Link IE Field Network function
related errors
CC-Link IE Field Network function
related errors
CC-Link IE Field Network function
related errors
Description
Error in the transient transmission
command.
Error in the transient transmission read/
write data quantity.
Error in the transient transmission attribute
code.
Error in the transient transmission access
code.
Transient transmission error detected.
Error in the transient transmission network
No.
Error in the transient transmission target
station No.
Error in the transient transmission
command.
Transient transmission error detected.
No station settings function in the target
station for which to change station number.
The target station for which to change
station number has not carried out baton
pass.
Invalid specification for target station for
which to change station number.
Station number set for target station for
which to change station number.
Corrective action
Correct the request command at the
transient request source, and run again.
Correct the device read and write data
quantity at the transient request source, and
run again.
Correct the attribute code at the data
request source, and run again.
Correct the access code at the transient
request source, and run again.
After resetting the MELIPC, execute the
request.
If the error code is displayed again even
after taking an action, consult your local
Mitsubishi representative.
• A cable test cannot be for a different
network destination. Correct "Test station
settings", and then carry out the cable
test again.
• Transient data that cannot be run for a
different network has been received.
Correct the network number or target
station number at the transient request
source, and then run again.
• Specifying the relay transmission station
and running a communications test is not
possible. Correct the "Communications
destination settings", and then carry out
the communications test again.
• Transient data of an application type that
cannot be run on own station was
received. Correct the application type or
target station number at the transient
request source, and then run again.
Correct the request command at the
transient request source, and run again.
• In engineering tools CC-Link IE Field
diagnoses, check the network status, and
take measures.
• Check that there are no faults with the
cable or a switching hub connections.
• If the error code is displayed again even
after taking an action, consult your local
Mitsubishi representative.
• When changing the station number of the
target station through a master station
online operation, there is no station
number settings function through an
online operation in the target station.
• Check if station number settings function
is possible using the target station
manual.
• If a supported model, consult your local
Mitsubishi representative.
Check the communications status of the
station for which to carry out station number
change.
• Station number change being carried out
for own station (master station).
• Check if the station number is not set in
the station for which to carry out station
number change.
• The station for which to carry out station
number change already has a station
number set.
• Check if the station number is not set in
the station for which to carry out station
number change.