No.
Name
SW0051
Own station link stop results
SW0052
System link start results
SW0053
System link stop results
SW0054
Temporary error disabled station
settings results
SW0055
Temporary error disabled station
settings clear results
SW0056
Reserved station specified temporary
clear request results
SW0057
Reserved station specified enabled
request results
SW0058
Total slave station number set value
SW0059
Total slave station number current value
SW005A
Maximum station numbers implementing
baton pass
SW005B
Highest station number implementing
data link
SW0060
Maximum link scan time
SW0061
Minimum link scan time
Description
Stores results from data link stop at 'own station link stop' (SB0001).
• 0: Normal
• From 1: Error details (error code)
(Turning OFF 'own station link stop' (SB0001) clears stored error details. )
<Conditions>
Enabled when 'baton pass status' of own station (SB0047) is OFF. When 'baton pass status of own
station' (SB0047) is ON (error), the data immediately before is retained.
Stores results from data link start at 'system link start' (SB0002).
• 0: Normal
• From 1: Own station error details (error code)
(Turning OFF 'system link start' (SB0002) clears stored error details. )
<Conditions>
Enabled when 'baton pass status' of own station (SB0047) is OFF. When 'baton pass status of own
station' (SB0047) is ON (error), the data immediately before is retained.
Stores results from data link stop at 'system link stop' (SB0003).
• 0: Normal
• From 1: Own station error details (error code)
(Turning OFF 'system link stop' (SB0003) clears stored error details. )
<Conditions>
Enabled when 'baton pass status' of own station (SB0047) is OFF. When 'baton pass status of own
station' (SB0047) is ON (error), the data immediately before is retained.
Stores results from requesting temporary error invalid station settings at a 'temporary error invalid
station settings request'(SB0010).
• 0: Normal
• From 1: Error details (error code)
(Turning OFF 'temporary error invalid request' (SB0010) clears stored error details. )
Stores results from clearing temporary error invalid station settings at a temporary error invalid clear
request (SB0011).
• 0: Normal
• From 1: Error details (error code)
(Turning OFF 'temporary error invalid cancel request' (SB0011) clears stored error details. )
Stores results from temporarily clearing of reserved stations at a 'reserved station specifications
temporary clear request' (SB0012).
• 0: Normal
• From 1: Error details (error code)
(Turning OFF 'reserved station specified temporary cancel request' (SB0012) clears stored error
details. )
Stores results from canceling temporary clearing of reserved stations at a 'reserved station specified
enabled request' (SB0013).
• 0: Normal
• From 1: Error details (error code)
(Turning OFF 'reserved station specified enabled request' (SB0013) clears stored error details. )
Stores the total number of slave stations set in a parameter (No. of slave stations).
(Range: 1 to 120)
Stores the total number of slave stations actually in data link (No. of slave stations).
(Range: 1 to 120, 0 (when own station disconnected))
Stores the highest station number of stations with the correct baton pass.
(Range: 1 to 120, 0 (when own station disconnected))
<Conditions>
Enabled when 'baton pass status of own station' (SB0047) is OFF. When 'baton pass status of own
station' (SB0047) is ON (error), the data immediately before is retained.
Stores the highest station number of stations with the correct data link.
(Range: 1 to 120, 0 (when own station disconnected))
<Conditions>
Enabled when 'data link stop status of own station' (SB0049) is OFF.
The maximum link scan time value during cyclic transmission is stored. (Unit: ms)
<Conditions>
Enabled when 'baton pass status' of own station (SB0047) is OFF. When 'baton pass status of own
station' (SB0047) is ON (error), the data immediately before is retained.
The minimum link scan time value during cyclic transmission is stored. (Unit: ms)
<Conditions>
Enabled when 'baton pass status' of own station (SB0047) is OFF. When 'baton pass status of own
station' (SB0047) is ON (error), the data immediately before is retained.