remote RUN/STOP
This section shows the operation methods of remote RUN/STOP.
■MI Configurator
Use a remote operation of MI Configurator.
[Online][Remote operation][MAIN RUN]/[STOP]
■SLMP
For details on SLMP, refer to the following manual.
SLMP Reference Manual
Precautions
Be aware of the following points when executing remote RUN/STOP because the STOP operation status of VxWorks part is
prioritized.
■Remote RUN/STOP operation
Remote RUN/STOP cannot be used when the STOP/MAIN RUN switch status is STOP. Set the STOP/MAIN RUN switch
status to RUN.
■STOP timing
This product enters the STOP status when a remote STOP was executed by MI Configurator.
■To change the remote STOP state to RUN again
Change the operating status by using remote RUN.
■User actions during a remote STOP
Data processing of a user program continues even when the operating status of this product is remote STOP. To separate the
processing of a user program by operating status, use the C Controller module dedicated function (CCPU_GetCpuStatus).
• Function list
Function name
CCPU_GetCpuStatus
For details on the C Controller module dedicated functions, refer to the following manual.
MELIPC MI5000 Series Programming Manual (VxWorks)
Description
To acquire the operating status of a MELIPC.
8 DIAGNOSTIC AND MAINTENANCE FUNCTIONS
8.3 Operating Status Management Function