Error code
8931H
8932H
8933H
8934H
8938H
893EH
893FH
8940H to 8946H
8949H
894AH to 894EH
8974H to 897AH
8980H to 8983H
8990H to 8991H
8993H to 899FH
89A0H to 89A6H
APPX
236
Appendix 2 List of Error Codes
Error name
Parameter write error
Flash ROM sum check error
Buffer memory access error
Buffer memory access error
Parameter acquisition error
Buffer memory access error
Synchronization cycle exceeded error
Buffer memory access error
Buffer memory access error
Buffer memory access error
Buffer memory access error
Buffer memory access error
Buffer memory access error
Buffer memory access error
Buffer memory access error
Description
Unable to write to flash ROM.
During parameter write, the power was
turned OFF, or remote RESET was carried
out.
Illegal write to buffer memory reserved area.
Illegal write to buffer memory reserved area.
Acquisition of parameters was not possible.
(Data error)
Illegal write to buffer memory reserved area.
Cyclic processing cannot be completed by
the start of the next synchronization cycle.
Illegal write to buffer memory reserved area.
Illegal write to buffer memory reserved area.
Illegal write to buffer memory reserved area.
Illegal write to buffer memory reserved area.
Illegal write to buffer memory reserved area.
Illegal write to buffer memory reserved area.
Illegal write to buffer memory reserved area.
Illegal write to buffer memory reserved area.
Corrective action
Turn the power supply OFF and ON. If the
same error is displayed again, this may
indicate a hardware fault. Consult your local
Mitsubishi representative.
Review parameter settings, and rewrite
parameter settings.
Turn the power supply OFF and ON. If the
same error is displayed again, this may
indicate a hardware fault. Consult your local
Mitsubishi representative.
Turn the power supply OFF and ON. If the
same error is displayed again, this may
indicate a hardware fault. Consult your local
Mitsubishi representative.
After writing parameters, turn the power off
and then on again, or carry out a remote
RESET.
Turn the power supply OFF and ON. If the
same error is displayed again, this may
indicate a hardware fault. Consult your local
Mitsubishi representative.
• Reduce cyclic points assigned and slave
connected numbers, and reduce link scan
time.
• If assigning link devices to a local station,
then assign continuously starting from the
link device header address (0).
• Change the synchronization period
setting to a longer setting than the current
setting.
Turn the power supply OFF and ON. If the
same error is displayed again, this may
indicate a hardware fault. Consult your local
Mitsubishi representative.
Turn the power supply OFF and ON. If the
same error is displayed again, this may
indicate a hardware fault. Consult your local
Mitsubishi representative.
Turn the power supply OFF and ON. If the
same error is displayed again, this may
indicate a hardware fault. Consult your local
Mitsubishi representative.
Turn the power supply OFF and ON. If the
same error is displayed again, this may
indicate a hardware fault. Consult your local
Mitsubishi representative.
Turn the power supply OFF and ON. If the
same error is displayed again, this may
indicate a hardware fault. Consult your local
Mitsubishi representative.
Turn the power supply OFF and ON. If the
same error is displayed again, this may
indicate a hardware fault. Consult your local
Mitsubishi representative.
Turn the power supply OFF and ON. If the
same error is displayed again, this may
indicate a hardware fault. Consult your local
Mitsubishi representative.
Turn the power supply OFF and ON. If the
same error is displayed again, this may
indicate a hardware fault. Consult your local
Mitsubishi representative.