No.
Name
SB006D
Own station port 2 error frame
reception current status (1)
SB006F
Own station port 2 error frame
reception detection status (latch) (1)
SB0074
Reserved station specification status
SB0075
Error disabled station settings status
SB0078
Network topology setting
SB007B
Data link abnormal station input data
status
SB007D
Retain/clear specification status at
STOP
SB008D
Own station port 2 error frame
reception current status (2)
SB008F
Own station port 2 error frame
reception detection status (latch) (2)
SB0098
Network configuration mismatch
occurrence status
SB0099
Connected device number excess
occurrence status
SB00A0
Each station baton pass error status
SB00A1
Master station baton pass error status
Description
Shows if a reception frame error of the circuit status caution level is currently occurring at own station
port 2.
• 0: A reception frame error. The circuit status caution level is not occurring.
• 1: A reception frame error. The circuit status caution level is occurring.
Shows if a reception frame error of the circuit status caution level occurred at own station port 2 when
the power supply was turned ON.
• 0: A reception frame error. The circuit status caution level is not occurring.
• 1: A reception frame error of the circuit status caution level occurred.
The reserved station specification status by parameters is stored. The station number of the station
configured as a reserved station can be checked by 'Reserved station settings status' (SW00C0 to
SW00C7).
• OFF: No specification
• ON: Specified
The error invalid station setting status by parameters is stored. The station number of the station
configured as an error invalid station can be checked by 'Error disabled station settings status'
(SW00D0 to SW00D7).
• OFF: No specification
• ON: Specified
Stores own station (master operating station) "Network Topology" status.
• OFF: Line/Star
• ON: Link connection
Stores own station "Data Link Error Station Setting" status.
• OFF: Clear
• On: Retain
The setting status of "Output retention & clear settings at STOP" of own station is stored.
• OFF: Hold
• ON: Clear
Shows if a reception frame error of the circuit status warning level is currently occurring at own station
port 2.
• 0: A reception frame error. The circuit status warning level is not occurring.
• 1: A reception frame error. The circuit status warning level is occurring.
Shows if a reception frame error of the circuit status warning level occurred at own station port 2 when
the power supply was turned ON.
• 0: A reception frame error. The circuit status warning level is not occurring.
• 1: A reception frame error of the circuit status warning level occurred.
Shows if the actual network configuration and the CC-Link IE Field network configuration settings
match.
• 0: Match
• 1: Mismatch
May turn ON regardless of the above-mentioned matching/mismatching after a slave station is
reconnected or added.
Shows if the number of slave stations connected to the master station is 120 or less, or 121 or more.
• 0: Number of connected devices 120 or less
• 1: Number of connected devices 121 or more
The number of connected stations is the total of currently connected slave stations (including sub-
master stations) and previously connected slave stations (disconnected stations).
Stores each station baton pass status.
• OFF: All stations normal
• ON: Error station found
In the event of faulty stations, the status of each station can be confirmed using 'each station baton pass
status' (SW00A0 to SW00A7).
<Conditions>
• Enabled when baton pass status of own station (SB0047) is OFF. When 'baton pass status of own
station' (SB0047) is ON (error), the data immediately before is retained.
• The status is not stored for the reserved stations and the station numbers after the maximum station
number.
Stores the master station (master operating station) baton pass error status.
• OFF: Normal
• ON: Error
<Conditions>
Enabled when 'baton pass status' of own station (SB0047) is OFF. When 'baton pass status of own
station' (SB0047) is ON (error), the data immediately before is retained.
Appendix 7 List of Link Special Relays
A
APPX
267