Required settings (if master station is selected by station type)
This shows parameters displayed inapplicable settings when master station is selected in essential settings station type.
Window
Displayed items
Parameters other than those below are the same as when local station is selected. ( Page 189 Basic settings)
■Synchronization communication settings
Item
Synchronization Cycle Setting Method
Synchronization Cycle Manual
*1
Setting
*1 When "Manual setting" is set for "Synchronization Cycle Setting Method", link scans for CC-Link IE Field Network will operate with the
cycle set for this item.
Description
Select the configuration method of the synchronization cycle.
The synchronization cycle is automatically set to the optimal
synchronization cycle as required by the number of slave devices
connected and cyclic assignment points.
Configure the cycle interval to synchronize communication with the
master station and slave stations.
Setting range
• Auto setting
• Manual setting
(Default: Auto setting)
• 0.888 ms
• 1.000 ms
• 1.777 ms
• 2.000 ms
• 3.555 ms
• 4.000 ms
(Default: 0.888 ms)
18 APPRICATION PARAMETERS
18.1 CC-Link IE Field Network Parameters List
18
Parameter
No.
0101H