Event code
Event type
534H
System
535H
System
541H
System
542H
System
800H
System
C00H
System
C01H
System
C02H
System
C10H
System
C11H
System
C20H
System
C21H
System
C22H
System
C24H
System
C25H
System
C27H
System
20011H
Operation
24000H
Operation
24001H
Operation
24010H
Operation
24011H
Operation
24020H
Operation
24021H
Operation
24030H
Operation
24100H
Operation
24F00H
Operation
Event category
Event
Information
<<Other station>> Reserved
station temporary clear settings
execute
Information
<<Own station>> Reserved
station enabled settings
instruction execute
Information
Reception parameter error clear
Information
<<Own station>> Reception
frame error, circuit status caution
level
Warning
Link-down
Warning
<<Own station>> Baton pass
interruption
Warning
<<Other station>> Baton pass
interruption
Warning
Other station access faulty
response
Warning
<<Own station>> Data link stop
Warning
<<Other station>> Data link stop
Warning
<<Other station>> parameter
error occurred
Warning
<<Other station>> Error
occurrence
Warning
Station duplication occurred
Warning
<<Other station>> Receive frame
error occurred
Warning
Reception parameter error
occurred
Warning
Transient reception failure
Information
CC-Link IE Field Network
Parameter changed
Information
Data link start instruction
Information
Data link stop instruction
Information
Temporary error disabled station
settings instruction
Information
Temporary error disabled station
clear instruction
Information
Reserved station temporary clear
settings instruction
Information
Reserved station temporary
enabled settings instruction
Information
Network number, station number
settings change instruction
execution
Information
<<Own station>> Parameter
change/new parameter received
Information
<<Own station>> CPU operating
status change detection
Description
Other station reserved station temporary clear
settings carried out.
Other station reserved station enabled settings
carried out.
Error of parameter received from master station /
control station was cleared. (Normal parameter was
received)
Reception frame error (Circuit status: Caution level)
occurred.
The CPU module has entered into the link-down
state as a result of an operation such as removing a
network cable connected to an external device.
Own station baton pass interrupted.
Other station baton pass interrupted.
• At other station access, a faulty response was
returned from the other station.
• At access from the other station, a faulty response
was returned to the other station.
Own station data link stopped.
Other station data link stopped.
Parameter error occurred in other station.
An error occurred on another station.
Master station or slave station duplication occurred
on the network.
Reception frame error occurred on another station.
Error detected in parameter received from master
station/administered station.
Own station transient frequency is too high,
therefore transient reception failed.
CC-Link IE Field Network Parameters have been
changed.
Data link start instruction to station or other station.
Data link stop instruction to station or other station.
Temporary error disabled station settings instruction
to slave station
Temporary error disabled station clear instruction to
slave station.
Reserved station temporary clear settings instruction
to slave station.
Reserved station temporary settings instruction to
slave station.
Network number, station number settings change
instruction for slave station given.
A parameter was changed. Alternatively, a new
parameter was received when the power supply was
turned ON.
Other station programmable controller CPU
operation status changed.
Appendix 3 Event List
A
APPX
255