No.
Name
SW0158 to
Port 2 error frame reception detection
SW015F
status (2)
SW0170 to
Each station parameter error status
SW0177
SW0180 to
Reserved station temporary clear
SW0187
settings status
APPX
280
Appendix 8 List of Link Special Registers
Description
Shows if a reception frame error of the circuit status warning level has occurred in the past at Port 2 of
each station from when the power supply was turned ON up to now.
• 0: A reception frame error. The circuit status warning level is not occurring.
• 1: A reception frame error. The circuit status warning level is occurring.
If 'clear communications error count' (SB0006) is ON, then the stored status is cleared.
The numbers within the following illustration indicate the station numbers. (: fixed at 0)
b15
SW0158
16 15 14 13 12
SW0159
32 31 30 29 28
112 111 110 109 108
SW015E
SW015F
-
-
-
-
-
<Conditions>
• Enabled when 'baton pass status' of own station (SB0047) is OFF.
• When 'baton pass status of own station' (SB0047) is ON (error), the data immediately before is
retained.
• Only enabled for stations with normal 'each station baton pass status' (SW00A0 to SW00A7).
Stores each station parameter error status.
• 0: No error
• 1: Error
The numbers within the following illustration indicate the station numbers. (: fixed at 0)
b15
SW0170
16 15 14 13 12
SW0171
32 31 30 29 28
112 111 110 109 108
SW0176
-
-
-
-
-
SW0177
<Conditions>
• Enabled when 'baton pass status' of own station (SB0047) is OFF. When 'baton pass status of own
station' (SB0047) is ON (error), the data immediately before is retained.
• Only enabled for stations with normal 'each station baton pass status' (SW00A0 to SW00A7).
• The status is not stored for the reserved stations and the station numbers after the maximum station
number.
Stores each station reserved station temporary clear settings status.
• 0: No reserved station temporary clear settings
• 1: Clearing reserved station temporary settings
The numbers within the following illustration indicate the station numbers. (: fixed at 0)
b15
SW0180
16 15 14 13 12
32 31 30 29 28
SW0181
112 111 110 109 108
SW0186
SW0187
-
-
-
-
-
<Conditions>
• Enabled when 'baton pass status' of own station (SB0047) is OFF. When 'baton pass status of own
station' (SB0047) is ON (error), the data immediately before is retained.
• Only enabled for stations with normal 'each station baton pass status' (SW00A0 to SW00A7).
• The status is not stored for the station numbers after the maximum station number.
b0
~
5
4
3
2
1
~
21 20 19 18 17
~
~
102 101 100 98 97
~
117 116 115 114 113
b0
~
5
4
3
2
1
~
21 20 19 18 17
~
~
102 101 100 98 97
~
117 116 115 114 113
b0
~
5
4
3
2
1
~
21 20 19 18 17
~
~
102 101 100 98 97
~
117 116 115 114 113