Execution timing of time setting
When "Use" was configured for "Time configuration (SNTP client)", time is configured at the following times.
• When the power supply of this product is turned ON or this product is reset
• Specified fixed cycle interval
• Specified fixed time
Precautions
■Communication timeout
A communication timeout results when there is no response from the SNTP server within 20 seconds from the time inquiry.
When a communication timeout occurs, there is no error, but the event of the timeout occurrence is saved to the event history.
( Page 253 Event List)
■SNTP Server
An SNTP server is necessary on the network connecting this product.
■Delay by communication time
The time to be set may be delayed by the time required to communicate with the SNTP server.
For a high-accuracy time setting, specify an SNTP server on the network that is as close to this product as possible.