Precautions
■When the MELIPC shutdown function is not completed
When the MELIPC shutdown function is run, the WIN RDY LED may continue to flash, and the MELIPC shutdown function
may not be run. Connect a display to this product to discover if there is a reason that the MELIPC shutdown function is not
finished (program is running, file saving, etc.). If there is a cause, eliminate it, and then shut down from the Windows Start
menu. If there is no cause, wait until shutdown is completed, and the WIN RDY LED turns off.
■If the MELIPC shutdown function was run when the Windows part is running
If the MELIPC shutdown function is run when the Windows part is running, the WIN RDY LED may continue to flash, and the
MELIPC shutdown function may not be run. If the WIN RDY LED continues to flash for a long time, connect a display to this
product, and then check whether the Windows part is running. If necessary, either run the MELIPC shutdown function again or
shut down Windows from the Windows Start menu.
■Functions that cannot be used for advance processing of the MELIPC shutdown function
Do not use the following functions for advance processing registered by the user. The MELIPC shutdown function may not be
completed.
• CCPU_MELIPCShutdown
• CCPU_WinReset
If processing that uses the above-mentioned functions was registered, and the MELIPC shutdown function was run, switch
the power supply of this product OFF to ON, and then change the registered processing.